Customization: | Available |
---|---|
Application: | Construction, Overhead, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Huadong factory wholesale aluminium conductor service drop abc cable
Phase Conductor : Stranded All Aluminum 1350 (AAC)
Neutral Conductor : AAC/AAAC/ACSR
Insulation : XLPE/ PE
Rated Voltage : 600V
Cores : 2+1, 3+1,4+1 etc
Other Standards: NFC 33-209/ BS 7870-5/ IEC 60502/AS/NZS/Ghost or according to your requirement.
Application: The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium,
insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation
as overhead power lines up to 1000V
Duplex Service Cable-AAAC
|
||||||||
Code* Word
|
Phase Conductor
|
Bare/Neutral Messenger
|
Weight /Per 1000 ft.(lbs.)
|
|||||
Size(AWG or kcmil)
|
Strand- ing
|
Insul. Thick. (mils)
|
Equiv. Dia. (AWG)++
|
Size++ (kcmil)
|
Strand- ing
|
XLPE
|
POLY
|
|
6201 Alloy Neutral-Messenger
|
||||||||
Chihuahua
|
6
|
1
|
45
|
6
|
7
|
7
|
65
|
65
|
Vizsia
|
6
|
7
|
45
|
6
|
7
|
7
|
68
|
68
|
Harrier
|
4
|
1
|
45
|
4
|
7
|
7
|
99
|
99
|
Whippet
|
4
|
7
|
45
|
4
|
7
|
7
|
103
|
103
|
Schnauzer
|
2
|
7
|
45
|
2
|
7
|
7
|
157
|
157
|
Heeler
|
1/0
|
9
|
60
|
1/0
|
7
|
7
|
250
|
250
|
Triplex Service Drop Cable-AAC
|
||||||||
Code* Word
|
Phase Conductor
|
Bare Neutral Messenger
|
Weight /Per 1000 ft.(lbs.)
|
|||||
Size(AWG or kcmil)
|
Strand- ing
|
Insul. Thick. (mils)
|
Size++ (kcmil)
|
Strand- ing
|
Rated Strength (lbs)
|
XLPE
|
POLY
|
|
AAC Neutral-Messenger
|
||||||||
Patella
|
6
|
7
|
45
|
6
|
7
|
563
|
103
|
103
|
Oyster
|
4
|
7
|
45
|
4
|
7
|
881
|
154
|
154
|
Clam
|
2
|
7
|
45
|
2
|
7
|
1350
|
233
|
233
|
Murex
|
1/0
|
7
|
60
|
1/0
|
7
|
1990
|
374
|
374
|
Purpura
|
1/0
|
9
|
60
|
1/0
|
7
|
1990
|
368
|
368
|
Nassa
|
2/0
|
7
|
60
|
2/0
|
7
|
2510
|
462
|
462
|
Melita
|
3/0
|
17
|
60
|
3/0
|
19
|
3310
|
562
|
562
|
Portunus
|
4/0
|
18
|
60
|
4/0
|
19
|
4020
|
696
|
696
|
Nannynose
|
336.4
|
19
|
80
|
336.4
|
19
|
6146
|
1118
|
1118
|
Quadruplex Service Drop-ACSR
|
||||||||
Code* Word
|
Phase Conductor
|
Bare Neutral Messenger
|
Weight /Per 1000 ft.(lbs.)
|
|||||
Size(AWG or kcmil)
|
Strand- ing
|
Insul. Thick. (mils)
|
Size++ (kcmil)
|
Strand- ing
|
Rated Strength (lbs)
|
XLPE
|
POLY
|
|
ACSR Neutral-Messenger
|
||||||||
Morochuca
|
6
|
1
|
45
|
6
|
6/1
|
1190
|
145
|
145
|
Chola
|
6
|
7
|
45
|
6
|
6/1
|
1190
|
153
|
153
|
Morgan
|
4
|
1
|
45
|
4
|
6/1
|
1860
|
217
|
217
|
Hackney
|
4
|
7
|
45
|
4
|
6/1
|
1860
|
229
|
229
|
Palomino
|
2
|
7
|
45
|
2
|
6/1
|
2850
|
347
|
347
|
Costena
|
1/0
|
9
|
60
|
1/0
|
6/1
|
4380
|
549
|
549
|
Grullo
|
2/0
|
11
|
60
|
2/0
|
6/1
|
5310
|
677
|
677
|
Suffolk
|
3/0
|
17
|
60
|
3/0
|
6/1
|
6620
|
837
|
837
|
Appaloosa
|
4/0
|
18
|
60
|
4/0
|
6/1
|
8350
|
1038
|
1038
|
Gelding
|
336.4
|
19
|
80
|
4/0
|
6/1
|
8350
|
1494
|
1494
|
Bronco
|
336.4
|
19
|
80
|
336.4
|
18/1
|
8680
|
1568
|
1568
|