Customization: | Available |
---|---|
Application: | Underground, Industrial, Power Station, Marine&Ship |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 8/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Enhanced THOF-500E THOF-E SHORE-TO-SHIP Rubber Power Cables for Cold Ironing
Description
|
Unit
|
Technical data
|
Size
|
Core*mcm
|
3*500
|
Type of cable
|
-
|
THOF
|
Voltage
|
V
|
600
|
Reference Standard
|
-
|
ICEA S-75-381
|
Conductor
|
||
Conductor material
|
-
|
Flexible tinned copper
|
Type
|
-
|
Class 5
|
Min. conductor stranded diameter
|
mm
|
22.15
|
Separator tape
|
--
|
Polyester tape*0.05mm
|
Insulation
|
||
Insulation material
|
-
|
EPR
|
Insulation color
|
-
|
Black, white, red
|
Nominal Thickness
|
mm
|
2.41
|
Sheath
|
||
Sheath material
|
-
|
Heavy duty CPE
|
Inner sheath thickness
|
mm
|
2.8
|
Reinforcement thickness
|
mm
|
0.38
|
Outer sheath thickness
|
mm
|
4.5
|
Overall diameter
|
mm
|
73.0
|
Approximate weight of completed cable
|
Kg/km
|
11791.4
|
Operating temperature
|
ºC
|
90
|
Conductor Voltage A.C of Testing
|
KV/MIN
|
3.5/5
|
Minimum Bending Radius
|
-
|
6*OD
|